Ladder diagrams: contacts, coils and start-stop logic

In factories, programs that decide when a motor runs or a door opens are often written as ladder diagrams. The name comes from rungs drawn like a ladder.

2026-11-23

Contacts and coils

A ladder diagram has two basic elements. A contact checks the state of an input; a coil drives an output. When a contact is closed — logically true — current flows and the coil to its right is energised. Everything else is built from this simple pair.

Start-stop logic

To start a machine you press a momentary button, but the machine must keep running after you release it. A seal-in circuit does this: the coil’s own auxiliary contact is wired in parallel with the start button. Pressing start energises the coil, and the auxiliary contact keeps the path closed.

Where the stop button goes

The stop contact is placed in series so that pressing it opens the path and the coil drops out. Together, seal-in and series stop form the basis of a great many ladder programs. Understanding these two ideas makes most diagrams readable.

Timers

Timers that produce an output after a set time are used as blocks in ladder logic. With an on-delay timer, the output switches on once the input has stayed active long enough. One use is giving a motor a warm-up period before it starts.

The scan cycle

Controllers scan the program from top to bottom again and again: read inputs, evaluate the logic, update outputs. Because of this cycle, the order of the rungs directly affects the result. Two programs with the same elements can behave differently when reordered.

Safety first

Ladder diagrams here are explained conceptually. Before working on a real machine, safety rules, emergency-stop circuits and approval by qualified personnel are required. For learning, low-voltage trainers and simulators let you try the logic without risk.

Frequently asked questions

What does a contact do in a ladder diagram?

It checks the state of an input. A closed contact lets current through and energises the coil placed after it.

Why is the auxiliary contact wired in parallel with start?

So the coil keeps itself energised after the momentary start button is released. This is called seal-in.

Why does rung order matter?

Because the controller scans top to bottom, reading inputs and updating outputs in that order. Reordering rungs can change the result.