Power Consumption Cheat Sheet
Every relation on this page comes from an existing DersTeders lesson, from Ohm and power basics to thermal design and supply selection.
- 10 documented power facts
- AC and DC power formulas
- Transistor loss and thermal rise
- PWM average and headroom rules
Power relations and examples
Use these documented relations to estimate what a circuit draws and where the energy is lost.
| Quantity | Documented formula or rule | Example or note from our lessons |
|---|---|---|
| Active power | P = V x I (with cos phi for AC) | Measured in watts; the real work done |
| Current from power | I = P / V | Used when selecting cable and fuse |
| Apparent power | S = V x I | Measured in volt-amperes |
| Power triangle | S² = P² + Q² | Power factor cos phi = P / S |
| BJT loss | P = VCE x IC | VCE(sat) is about 0.2 V in saturation |
| MOSFET loss | P = IC² x Rds(on) | A high Rds(on) increases heating |
| Temperature rise | dT = P x RθJC | Junction limit typically 150 °C |
| PWM average voltage | Uout = D x supply, D = ton / T | 24 V at 35% duty gives 8.4 V |
| Supply selection | Match voltage, then allow current headroom | Current capacity is offered by the supply, not pushed |
| Energy management | Separate heavy loads and shorten idle loops | Our workshop recommends separate supplies and sleep modes |
How to use this reference
Find the current first with I = P / V when you know the load power and the supply voltage. Our installation lessons use this before choosing cable and protection.
For AC circuits, keep the three powers separate: active P does the work, reactive Q moves between source and inductors or capacitors, and apparent S is what the source must provide. The documented triangle is S² = P² + Q².
When a transistor switches a load, calculate its own loss. Use P = VCE x IC for a BJT and P = IC² x Rds(on) for a MOSFET, then turn that loss into a temperature rise with dT = P x RθJC.
For PWM-driven loads, use the average rather than the peak. Our material gives 24 V at 35% duty as 8.4 V average.
Choose the supply by matching the voltage first and then adding current headroom. Extra current capacity lets the supply run cooler and handle brief peaks; extra voltage is not a substitute.
Keep high-current loads such as motors and relays on their own supply, join the grounds, and reduce unnecessary continuous current in long loops.
Related DersTeders pages
Active, reactive and apparent powerThe source of the power triangle and power factor.Power supply basicsVoltage matching, headroom and decoupling.Electrical powerFurther worked power calculations.Keep the reference close. Create a free account to save your place, open the simulators and follow the full electronics guides.
No installationFrequently asked questions
What is the basic power formula?
P = V x I. For AC circuits with a phase angle our material uses P = V x I x cos phi.
How do I estimate transistor heating?
Find the device loss with P = VCE x IC or P = IC² x Rds(on), then multiply by RθJC to get the temperature rise.
What does 35% PWM mean for a 24 V supply?
The average output is 8.4 V, because average voltage equals duty cycle multiplied by supply voltage.
Should I pick a supply with more current?
Yes, allow headroom above the measured maximum. Our guide says current capacity is something the supply offers and extra capacity runs cooler.
Interactive circuit guide
Run the simulation, follow the build steps one by one and try it in our real app.
Stopped
Step-by-step build