Chemical analysis

Chemistry · Grades 7-10

What will we learn in this lesson

Chemists identify substances by measuring properties. We will use melting and boiling points to judge purity, read a chromatogram, calculate an Rf value, and see how distillation separates liquids with different boiling points. The worked examples practice the Rf calculation.

Prerequisite: before you begin

You should know that a pure substance consists of a single element or compound, while a mixture contains more than one substance. Chromatography separates mixtures because components travel different distances on the same medium.

These definitions are not isolated labels. pure substance and chromatography appear together in almost every question on Chemical analysis; if either meaning is unclear, the rest of the reasoning becomes hard to follow. The same applies to stationary phase, which completes the basic vocabulary of the topic. Keep this short list beside you while working through the examples below.

A simple example

A pure substance has a sharp melting point and a sharp boiling point. An impure substance melts and boils over a range of temperatures. A pure substance also produces a single spot on a chromatogram. These tests are useful because they give measurable evidence instead of relying on appearance.

In paper chromatography, the paper is the stationary phase and the solvent is the mobile phase. Substances that dissolve better in the solvent travel further up the paper. A substance that sticks strongly to the paper moves less far.

A harder example

The Rf value is the distance moved by the substance divided by the distance moved by the solvent front. Because both distances depend on the conditions, an unknown substance can be identified by comparing its Rf value with a known standard run under identical conditions. A matching value is evidence, not absolute proof, since different substances can share an Rf value in one solvent.

Distillation separates liquids with different boiling points: the lower-boiling liquid vaporises first and is condensed elsewhere. A residue is the solid left behind, for example after evaporation of a solution.

These facts are useful when a question gives you more than one possible route: they tell you which quantity is being described and which relationship applies. State that relationship in words before you substitute any values, then check that your answer is consistent with it.

An immediate consequence is that Filtration separates undissolved solids from liquids.

This point is easy to overlook, yet Filtration separates an insoluble solid from a liquid by passing the mixture through filter paper, which holds back the solid.

A starting point for this topic is that Crystallisation can purify a solid, because pure crystals form as the solution cools while impurities remain dissolved.

Worked example step by step

Question 1. A spot moves 3 cm and the solvent front moves 12 cm. What is the Rf value?

  1. Rf equals distance moved by the substance divided by distance moved by the solvent front.
  2. Calculate 3 divided by 12, which equals 0.25.
  3. Rf is 0.25. It has no units because it is a ratio of two distances.

Question 2. A sample has an Rf of 0.6 and a known substance has an Rf of 0.6 under the same conditions. What does this suggest?

  1. Compare the values: they match.
  2. Matching values under identical conditions are consistent with the sample being the same substance.
  3. It suggests the substances may be the same; another test would strengthen the identification.

Question 3. A spot moves 2 cm and the solvent front moves 10 cm. Find Rf.

  1. Divide 2 by 10.
  2. The result is 0.2.

Before substituting into any calculation, write the relationship down: Rf value — Rf = distance moved by substance / distance moved by solvent front (dimensionless). A formula stated at the start makes it much easier to spot a wrong answer at the end.

Concept comparison table

TestWhat is measuredPure or impure result
Melting pointTemperature range of meltingSharp for pure, broad for impure
Boiling pointTemperature range of boilingSharp for pure, broad for impure
ChromatographyNumber of spots and Rf valuesOne spot for a pure substance
DistillationDifferent boiling pointsSeparates liquids in a mixture

Quick reference for Chemical analysis:

NameExpression / valueUnits
Rf valueRf = distance moved by substance / distance moved by solvent frontdimensionless

The expression column shows what is related to what; the units column reminds you that a numerical answer is incomplete without its unit.

Common mistakes

Summary

Purity is tested with sharp melting and boiling points and with chromatography, where a pure sample gives one spot. Components that dissolve better in the solvent move further, and Rf is their distance divided by the solvent-front distance. Standards must be run under identical conditions. Distillation separates liquids by boiling point.

To connect the ideas, remember that filtration separates undissolved solids from liquids. filtration separates an insoluble solid from a liquid by passing the mixture through filter paper, which holds back the solid. crystallisation can purify a solid, because pure crystals form as the solution cools while impurities remain dissolved. Read together, these statements describe one coherent process rather than separate facts.

Check your understanding

  1. How does an impurity affect a melting point?
  2. A spot moves 4 cm and the front moves 8 cm. Calculate Rf.
  3. Why must a standard be run under the same conditions as the sample?
  4. What does distillation separate?

Beyond this topic: the following are deliberately not covered here and may appear later in the Grades 7-10 course: gas chromatography column design; mass spectrometry.

Definitions

pure substance
A substance containing only one type of material.
chromatography
A method for separating substances by how far they travel through a medium carried by a solvent.
stationary phase
The material that stays fixed, such as the paper in paper chromatography.
Rf value
The distance a substance moves divided by the distance the solvent front moves.
stationary phase
The material, such as the paper in chromatography, that does not move and holds the components of a mixture back by different amounts.
residue
The solid that remains on the filter paper after filtration.

Key facts

Common mistakes and corrections

Common mistake

Pure substances always contain several elements.

Correction

A pure substance contains only one substance, which may be an element or a compound.

Common mistake

Impure substances have a sharp melting point.

Correction

Impure substances melt over a range of temperatures.

Common mistake

A pure substance always melts over a range of temperatures.

Correction

A pure substance melts at one fixed temperature, while an impure substance melts over a range of temperatures.

Worked examples

A spot moves 3 cm and the solvent front moves 12 cm. What is the Rf value?

3 / 12 = 0.25.

0.25

A sample has an Rf of 0.6 and a known substance has an Rf of 0.6 under the same conditions. What does this suggest?

Matching Rf values under the same conditions suggest the same substance, though this is supporting evidence only.

The substances are probably the same

Outside the scope of this topic

Source: data/global-olgu/canada/ca-chem-chemical-analysis.json