
Build it for real
To build this project for real, get the parts from hobidevre.com → hobidevre.com →
More build guides: hobidevre.com/blog
Disconnect power first
Unplug the USB cable or external supply before touching the circuit. A short can heat a wire or damage a board in seconds, and a meter set to resistance must never be connected to a live circuit.
If anything feels warm or smells burnt, stop and let it cool before inspecting.
Know the breadboard layout
The five holes in a numbered row are connected horizontally, so two component legs in the same row are directly joined. The long power rails run vertically, and on many boards each rail is split in the middle.
Assuming a rail is continuous across a split is a classic cause of a circuit that works at one end and fails at the other.
Common short patterns
Two LED legs seated in the same row, a bare wire bridging the positive and negative rails, or a resistor whose trimmed legs touch are all frequent causes.
Another pattern is a component lead pushed through to the opposite side of the board and touching a different row. Lift the board and check both sides.
Use continuity mode
Set the meter to beep or resistance and, with power off, probe the two rails. A continuous beep between positive and negative confirms a short. Then remove wires one at a time until the beep stops; the last wire removed is the culprit.
A reading near zero means a direct connection. A high or changing reading is normal for components still in circuit, so disconnect parts when narrowing it down.
Inspect visually and by touch
Look for stray wire ends, solder whiskers and components pressed flat against each other. Gently tug each jumper: one that lifts out easily was never seated properly.
A regulator that got hot is a strong clue that its output and ground were joined. Check around that part first.
Limit current when you power up again
After clearing the short, power the circuit through a current-limited supply or add a resistor in series for the first test. If current stays low, the fault is gone.
Never simply keep trying with a fresh board; a repeated short indicates a wiring mistake that will recur.
Rebuild from a verified layout
If the fault refuses to reveal itself, rebuild the circuit on a clean area of the board from a known-good diagram, moving one wire at a time from the old layout.
Draw the rows and rails on paper first. A five-minute sketch prevents most shorts before they happen.
Get the parts
If you want to build this project in real life, you can get the parts from hobidevre.com.
Frequently asked questions
How do I know if a short damaged my board?
Power the bare board with no circuit attached. If the power LED works and a blank sketch uploads, the board is probably fine.
Why did my regulator get hot?
Its output was likely joined to ground. Power off immediately and check for a direct connection across the rails.
Are the five holes in a row connected?
Yes, horizontally. The two vertical power rails normally are not connected to each other, and many are split in the middle.