What will we learn in this lesson?
Chemical analysis identifies substances and checks purity. In this lesson you will learn the simple tests for hydrogen, oxygen, carbon dioxide, chlorine and water, how flame tests identify metal ions, and how paper chromatography separates dissolved substances. You will calculate an Rf value, understand why the starting line is drawn in pencil, and interpret a melting range as evidence of impurity.
Prerequisite knowledge
You should know that a pure substance contains only one element or compound and has a sharp melting point, while a mixture melts over a range. You should also know that a solvent is a liquid that dissolves a substance, such as water or ethanol. Dividing one length by another gives a ratio with no units.
A simple example
A chemical test identifies a substance by a characteristic observation. Hold a lighted splint to hydrogen and it gives a squeaky pop. Oxygen relights a glowing splint. Carbon dioxide turns limewater milky, and chlorine bleaches damp litmus paper. Water turns white anhydrous copper(II) sulfate blue. Blue litmus paper turns red in acid and stays blue in a neutral solution.
Flame tests identify metal ions by the colour they give to a flame; lithium gives a red flame, for example. Each test produces an observation that can be recorded and compared with a known result.
Chromatography separates substances according to how strongly they dissolve in a solvent and how strongly they stick to the paper. The solvent travels up the paper, carrying the dissolved substances with it; substances that dissolve more readily travel farther. The solvent front is the furthest point reached by the solvent. Paper chromatography is used in forensic science and food testing to compare a sample with substances of known identity.
A harder example
Why is the starting line drawn in pencil? Ink would dissolve in the solvent and move up the paper, adding extra spots that could be mistaken for the sample. Pencil does not dissolve, so the line stays where it was drawn and the distances measured are reliable.
Purity can also be checked by melting point. A pure substance has a sharp, fixed melting point; an impure substance melts over a range and at a lower temperature than the pure material. A sample that melts well below the known melting point of a pure substance is therefore impure.
Results should be recorded with both the observation and the conclusion, in enough detail that another person can repeat the test and check the result. Writing only "it changed colour" is not enough; name the reagent, the colour or sound observed, and what it identifies.
Step-by-step worked example
Calculate an Rf value when a spot moves 3 cm and the solvent front moves 6 cm.
- Write the relationship: Rf = distance moved by spot / distance moved by solvent front.
- Substitute the measurements: Rf = 3 / 6.
- Calculate: 3 ÷ 6 = 0.5.
- State the result: Rf = 0.5, with no units because it is a ratio.
For a spot at 5.0 cm and a solvent front at 8.0 cm, Rf = 5.0 / 8.0 = 0.625, which rounds to 0.63 to two decimal places. Both distances must be measured from the same starting line. If one measurement is taken from a different point, the ratio is meaningless.
Concept comparison table
| Test | Observation | Identifies |
|---|---|---|
| Lighted splint | Squeaky pop | Hydrogen |
| Glowing splint | Relights | Oxygen |
| Limewater | Turns milky | Carbon dioxide |
| Damp litmus paper | Bleached | Chlorine |
| Anhydrous copper(II) sulfate | White to blue | Water |
| Flame test | Characteristic flame colour | Metal ions, for example lithium giving red |
| Evidence | Pure substance | Mixture |
|---|---|---|
| Melting point | Sharp and fixed | Range of temperatures, lower than pure material |
| Chromatogram | One spot | Several spots |
Common mistakes
Mistake 1: "A mixture has a sharp melting point." A mixture melts over a range; a pure substance melts sharply.
Mistake 2: "Pencil is used because it is colourful." Pencil is used because it does not dissolve in the solvent.
Mistake 3: "Pure water is a mixture of hydrogen and oxygen." It is a compound of the two elements.
Mistake 4: measuring the solvent front from the wrong origin. Measure both the spot and the solvent front from the pencil line.
Summary
- A pure substance has a sharp melting point and boiling point.
- An impure substance melts over a range and at a lower temperature.
- The chromatography starting line is drawn in pencil because pencil does not dissolve.
- Hydrogen gives a squeaky pop; oxygen relights a glowing splint.
- Carbon dioxide turns limewater milky; chlorine bleaches damp litmus.
- Water turns anhydrous copper(II) sulfate from white to blue.
- Flame tests identify metal ions by flame colour.
- Chromatography compares a sample with known substances in forensic and food testing.
- Record observations and conclusions so another person can repeat the test.
- Rf equals spot distance divided by solvent front distance.
Check your understanding
- Which gas relights a glowing splint? Oxygen.
- Why is the chromatography line drawn in pencil? Pencil does not dissolve in the solvent.
- A spot moves 3 cm and the solvent front 6 cm. Find Rf. 0.5.
- What does limewater detect? Carbon dioxide, which turns it milky.
- What does a melting range indicate? The sample is impure.
- What observation identifies hydrogen? A squeaky pop with a lighted splint.
Definitions
- pure substance
- a substance containing only one element or one compound
- formulation
- a mixture designed to have a particular purpose
- chromatography
- a technique that separates substances by how strongly they dissolve in a solvent and stick to paper
- Rf value
- the distance moved by a spot divided by the distance moved by the solvent front
- melting point
- the temperature at which a solid changes into a liquid
- chemical test
- a simple test used to identify a substance
- solvent
- A liquid that dissolves a substance, such as water or ethanol.
- solvent front
- The furthest point reached by the solvent on chromatography paper.
Key facts
- A pure substance has a sharp, fixed melting point and boiling point.
- An impure substance melts over a range of temperatures and at a lower temperature than the pure substance.
- The starting line in chromatography is drawn in pencil because ink would dissolve and move.
- Hydrogen is identified by a squeaky pop when a lighted splint is held to it.
- Oxygen relights a glowing splint.
- Carbon dioxide turns limewater milky.
- Chlorine bleaches damp litmus paper.
- Water turns anhydrous copper(II) sulfate from white to blue.
- A chemical test identifies a substance by a characteristic observation, such as a colour change, a gas that relights a splint, or a sound.
- Chromatography is used in forensic science and food testing to compare a sample with substances of known identity.
- Test results should be recorded with the observation and the conclusion, so that another person can repeat the test and check the result.
- Flame tests identify metal ions by the colour they give to a flame, such as lithium giving a red flame.
- Blue litmus paper turns red in acid and stays blue in a neutral solution.
- Rf value
- Gas chromatography and mass spectrometry
- Quantitative titration and instrumental analysis (extension)
Common mistakes and corrections
Common mistake
A mixture has a sharp melting point.
Correction
A mixture melts over a range of temperatures; a pure substance has a sharp melting point.
Common mistake
Pencil is used because it is more colourful.
Correction
Pencil is used because it does not dissolve in the solvent.
Common mistake
Pure water is a mixture of hydrogen and oxygen.
Correction
Pure water is a compound of hydrogen and oxygen.
Worked examples
A spot moves 3 cm and the solvent front moves 6 cm. What is the Rf value?
Rf = distance spot / distance solvent front; Rf = 3 / 6; Rf = 0.5
0.5
A spot moves 5.0 cm and the solvent front moves 8.0 cm. What is the Rf value to 2 decimal places?
Rf = 5.0 / 8.0; Rf = 0.625; Rf = 0.63
0.63
A sample melts over a range of temperatures well below the known melting point of a pure substance. What does this show?
a pure substance has a sharp melting point; a range of melting temperatures below the known value shows impurity
The sample is impure.
Outside the scope of this topic